Cannot connect to the SQDR Control Center

Symptom

The browser can't open the SQDR Control Center at http://<server>:8080/SQDRManager (or https://<server>:8443/SQDRManager). For sign-in errors once the page opens, see More about signing in.

What to do

  1. On the Stelo VM, check that the three Stelo Capture services are running: SQDR Plus Launch Agent, SQDR Plus Jetty and SQDR Plus Derby (see Stelo Capture services).
  2. If a service doesn't start or stops again, read its wrapper.log, under C:\ProgramData\StarQuest\sqdrplus (see Log files and folders).
  3. Check the Windows event log (eventvwr.msc, System and Application) for errors starting these services.
  4. Check that a firewall doesn't block the SQDR Control Center's ports, 8080 (HTTP) and 8443 (HTTPS) by default, or the ports chosen at installation (see Open the SQDR Control Center). On the server itself, try http://127.0.0.1:8080/SQDRManager: if that works and another computer can't connect, the problem is the network or the firewall.

Docker

In the Stelo Replicator container, the Stelo Capture logs are under /var/sqdrplus (see Logs), and the SQDR Control Center is controlled with /etc/init.d/sqdr-jetty (see Start and stop the services).

The Data Replicator Manager can't connect to the Replicator Service

Symptom

The Data Replicator Manager says "Cannot connect to server at host ... and port ...", or "Unable to connect to the server", or Server Test reports that the service is unavailable.

What to do

  1. Check what Server Test reports, and follow its advice for the host, port, network and firewall.
  2. Check that the StarQuest Data Replicator service (SQDRSVC) is running (in Docker, sqdrsvc-status). If it doesn't start, see The Replicator Service doesn't start.
  3. If the service runs, read its log for errors such as expired passwords or licenses (see Log files on the service host).
  4. Check that the Windows accounts that run the service or reach the control database aren't disabled and their passwords haven't expired.
  5. Check the control database:
    • Db2 for LUW: check that the Db2 service is running, and that the control database user can sign in, for example with db2 connect to SQDRC user sqdr in a Db2 command window.
    • SQL Server: check that the SQL Server service (MSSQLSERVER, or MSSQL$<instance> for a named instance) is running, and that the login can sign in and use the control database. The login must be mapped to a user of the control database (see SQDRSVC error 1010 or 2012).

The SQDR Control Center misbehaves after an upgrade

Symptom

After an upgrade of Stelo Capture, the SQDR Control Center doesn't behave as expected: new functions don't work, or you get "Request failed. 500 the call failed on the server; see server log for details". The server log is the Stelo Capture Jetty service's wrapper.log, in C:\ProgramData\StarQuest\sqdrplus\jetty\logs.

Cause

The browser still runs the earlier release's scripts from its cache.

What to do

Reload the page with Ctrl+F5, which reloads the scripts. If signing in fails with "The response could not be deserialized.", see More about signing in.

The Data Replicator Manager is slow or unresponsive

Right after the Replicator Service starts. The service connects once to every source and destination to read their database information, even those no subscription uses, and keeps trying the ones it can't reach. Until then, the Data Replicator Manager can be slow to connect or to respond. Read the service log for what it's waiting for (see Logs), and remove sources and destinations you no longer use.

While in use, for example when you expand the tree: with many subscriptions and a lot of replication history, the control database grows and slows the service down. Keep the history limited (see Keep history limited and History Logging). If you upgraded to 7.0, check those limits: a limit of 0 changed meaning (see How long history is kept).

The Control Center shortcut opens the wrong port

Symptom

You removed Stelo Capture and installed it again with another port for the SQDR Control Center, and the SQDR Control Center shortcut still opens the earlier port.

What to do

Sign out of Windows and sign in again.